Tap the clamp with a mallet or similar tool to ensure uniform loading during clamp tightening. Figure 1. Pentair Pool Products Hawkins Ave. This distance will vary with the model of filter you are using.

See Table 1 for the required vertical clearance. Rotate the High Flow manual air relief valve to safely direct purged air or water.

Water discharged from an improperly positioned filter or valve can create an electrical hazard as well as damage property. Install the drain hose on your High Flow manual air relief valve. Determine drainage area for the water purged from the filter. The filter base has four 4 drainage holes. Place the end of the drain hose into one of these holes if you wish to drain into the base. The drain hose holders can be mounted on the side of the filter tank with the self-adhesive backing provided.

Be sure the area where the hose holders are mounted is free of dirt, grease, or water. Insert the drain hose through the hose holders and clamp the end of the hose to the High Flow manual air relief valve with the plastic clamp provided.

Push-Pull valve b. Multiport valve c. Bulkhead union set 8. Filter plumbing connections are provided with an O-ring seal. Do not use pipe joint compound, glue or solvent on the bulkhead connections. Never subject this filter to pressure in excess of this amount - even when conducting hydrostatic pressure tests.

Pressures above 50 psi can cause the lid to be blown off, which can result in severe injury, death or property damage. In most cases, the maximum working pressure will be stated on each component of the system. If doubt exists as to the pressure to which the system will be subjected, install an ASME approved automatic Pressure Relief or Pressure Regulator in the circulation system for the lowest working pressure of any of the components in the system. Position the filter and High Flow manual air relief valve to safely direct water drainage and purged air or water.

Water discharged from an improperly positioned filter or valve can create an electrical hazard that can cause severe personal injury as well as damage property. Table 1. Vertical Model Size Clearance Req. When clamped properly and operated without air in the water system, this filter will operate in a safe manner. Diatomaceous earth is the substance that filters the water, the filter cloth merely supports the diatomaceous earth.

Operating without diatomaceous earth will damage filter elements and shorten filtering cycles. Turn the pump off and shut off any automatic controls to ensure that the system is not inadvertently started during servicing. Open the High Flow manual air relief valve.

Never attempt to assemble, disassemble or adjust the filter clamp while there is any pressure in the filter. Be certain the O-ring is in position in the lower tank half. Press the filter lid over the lower tank half sandwiching the O-ring in between. Holding the ends of the filter clamp apart, position the center segment of the filter clamp over both upper and lower tank flanges.

Bring the ends of the filter clamp together, while inserting the T-Bolt into the trunnion; see Figure 2. Hand-tighten nut. Recheck filter clamp for proper seating on tank flanges. Figure 2. Then tap around the outside of the filter clamp with a mallet or similar tool to ensure uniform loading and proper seating of the clamp. Continue tapping and tightening until the spring coils touch each other. Do not tighten beyond this point. The spring coils should be checked at least once per month to ensure that they continue to touch each other, indicating that the clamp is under sufficient tension.

If coils fail to touch repeat step B. Open the High Flow manual air relief valve until it snaps into the full open position this only requires a quarter turn counter clockwise.

Stand clear of the filter tank, then start the pump. Close the High Flow manual air relief valve after a steady stream of water appears. The system is not working properly if: a. The pressure gauge indicates pressure before water out-flow appears. CAUTION The following information should be read carefully since it outlines the proper manner of care and operation for your filter system.

You can expect maximum efficiency and life from your filtration system by following these instructions and taking the necessary preventative care. Push-Pull Valve. Push handle on valve down with slight twisting motion as far as it will go. Lock upper pin in cap. Open High Flow manual air relief valve on the filter.

This is your normal flow from the pump through the filter to the pool. You may have to do this several times. With the pump running and the pool skimmer valve open, pour the mixture directly into the skimmer.

E g. Clean your filter when pressure reads between 10 to 12 psi higher than the original starting pressure.

Your filter pressure reading will increase as it removes dirt from your pool. However, this build-up of pressure will vary due to different bathing loads, temperature, weather conditions, etc. Table 2 Weight of No. Filter Area sq. Diamote Coffee Cans 24 2. Full-Flow Valve. Open High Flow manual air relief valve. Your filter elements must be precoated with this material in order to protect their surfaces and provide the most efficient filtering action.

Refer to Table 2 for the proper quantity to use with your filter. The Titan RPM Vertical Grid Series filters are listed with the appropriate amounts of diatomite to be used to precoat the filter elements. Do not "pack" or compress diatomite into the coffee can. If there is a separate skimmer line and main drain line plumbed to the pump, close the main drain valve. Follow the instructions provided with your pump. Care should be taken not to lose or damage the internal air relief, located on top of the manifold.

After coating the stand-pipe O-ring generously with a silicone base lubricant, replace the element assembly in the filter tank, seating it firmly in place. Place and press the filter lid over the lower tank half sandwiching the O-ring in between, after coating it generously with a silicone base lubricant. Never attempt to assemble, disassemble or adjust the filter clamp while there is pressure in the filter.

Turn skimmer to full skim position and close main drain line. Remove pump lid and clean basket. Valve Procedures. Turn handle clockwise to lock lower pin in underside of cap. Replace clean bag and set bag in seat curved portion of Separation Tank. Put plastic hold-down in place to prevent earth from going back into pool, one double bag is furnished with Separation Tank.

Contents are to be placed in a waste or trash container, clean the bag and re-insert in the Separation Tank.

Your filter is now in operation. E 2 Open the High Flow manual air relief valve until it snaps into the full open position this only requires a quarter turn counter-clockwise.

To completely disassemble the filter element assembly for a more thorough cleaning of the individual elements, stand the element assembly on the deck exactly as it comes out of the filter with the manifold on top.

Disassembly: a. Remove plastic stand-offs from tie rod ends. Remove the two thumb nuts. Remove top manifold by holding lift handles and pulling straight up. Gently remove the plastic template from the elements.

Remove elements one at a time from the bottom spreader. Cleaning with water: a. Removal of these deposits may be accomplished by soaking the filter elements in six 6 parts water to one 1 part hydrochloric acid muriatic acid.

Soak for at least four 4 hours in a plastic tub or pail. Rinse filter elements thoroughly in tap water. Reassemble: a. This will keep the elements positioned correctly. Using moderate force push down on the manifold to seat it on to the elements. Replace the two thumb nuts hand tight and replace the two plastic stand-offs.

Replace the completed element assembly into the filter tank. Rinse the air bleed tube with water to clean away built-up debris. Normally, this is all that is necessary to properly clean the tube.

If the tube appears to be clogged or damaged, follow the remaining steps of this section below. Remove the snap clamp from the tube assembly as follows: a. Twist the two push tabs in opposite directions. Spread the clamp open, and lift off of the tube, see Figure 3. Remove the polyester sock from the tube. Clean the sock by rinsing with water.

Air Bleed Tube Adap. Inspect the air bleed tube. If there is any lodged debris, remove the debris using a toothpick or pipe cleaner. Reinstall the sock onto the tube. Slide the clamp onto the tube assembly, position it past the rib near the bottom of the tube, and close the clamp by squeezing the push tabs.

If any parts appear to be damaged, replace them immediately. With the High Flow manual relief valve attached to the filter tank, pull out the locking tabs and remove the valve stem and cover assembly with a counterclockwise and lifting motion, see Figure 4. Figure 4. Clean debris from the valve stem and body. Ensure that the O- rings are in good condition, properly positioned, and lubricated with a silicone base lubricant.

Correct any conditions in your filtration system that allow air to enter the system. Some common ways to identify air entering the system are listed below.

Air bubbles or low water level in pump hair and lint pot are caused by the following factors: 1 Low water level. Air is discharged from the High Flow manual air relief valve on top of the filter when the valve is opened with the pump running, see steps A. Removal of these may be accomplished by soaking the grids in six 6 parts water to one 1 part hydrochloric acid muriatic acid. In most cases, pool owners are dismayed by the undesirable color and appearance of water in a newly filled pool.

Plaster dust can be responsible for short filter runs, requiring frequent cleaning. If it turns freely then the pump must be disassembled and the impeller checked to see if it is clogged. If it is not frozen or clogged then there is an obstruction in the line between the pool and the pump.

E F. Check the operation of your pressure gauge in the following manner. The pressure gauge should indicate pressure when the system is operating. The pressure gauge should be readable and not damaged in any way.

Item Part Description No. E Vertical Grid Filter s This flow rate is based of 2. P roduct sq. Height GPM GPH 6 hour 8 hour 24 37" 60 3, 21, 28, 36 43" 90 5, 32, 43, 48 49" 7, 43, 57, 60 55" 9, 54, 72, Rev. Filter under high standards of workmanship and with high quality materials.

The obligation of Pentair Pool Products under this warranty will be limited to either repair or replacement of the filter tank, at Pentair Pool Products option. Any cloth materials, synthetic or natural, contained in the filter. Any components manufactured by other companies and installed by Pentair Pool Products such as air or water valves, gauges, plumbing, fittings, pipes, bolts, nuts, cartridges, etc.

Problems resulting from failure to comply with instructions contained in the Owner's Manual. Problems resulting from abuse, misuse, negligence or accident by any party other than Pentair Pool Products. Problems resulting in whole or in part from alteration or modification of the filter by any party. Failures due to chemical corrosion caused by failure to maintain the water chemistry in conformity with the standards of the swimming pool and spa industry.

Pentair Pool Products is not, however, responsible under this warranty for any cost of shipping or transportation of the filter or part thereof to or from the Customer Service Department. Also, Pentair Pool Products is not liable for any loss of time, inconvenience, incidental expenses such as telephone calls, labor or material charges incurred in connection with the removal or replacement of the equipment, or any other incidental or consequential damages.

Los Angeles Ave. Upon receipt of this communication, Pentair Pool Products will promptly notify the customer of the address to which the defective item may be shipped. The customer shall then ship the item, freight prepaid, to the address indicated together with a letter stating the model number, serial number, and the date of purchase of the item which is claimed to be defective, and the name and address of the consumer and a brief description of the problems encountered.

Accordingly, Pentair Pool Products is not responsible for any such warranties or representations. E Short-link Link Embed. Share from cover. Share from page:. Allow sufficient space above the Page 4 and 5: 5. Replace tank top and carefully f Page 8 and 9: 5. More magazines by this user. Results 1 to 9 of 9. Love the site and see I'm not alone with lots of pool issues.

Any help you folks can provide would be greatly appreciated! I assume that you have called the company that makes it and also looked on their website to see if it can be downloaded? I'll ask Waterbear, but I don't have any of those manuals. Join Date Dec Location S. E Maine Age 55 Posts 1, Can you post a pic or 2?

I know a bit about DE filters and may be able to help. I have been searching across the internet on-and-off for some time but "no joy" in finding an owner's manual.

Anyway, after a night's sleep and a relaxing morning cup of coffee, I went back out to tackled the filter grid. Link to PoolCenter. I'll send pics and pool specs a bit later.

I'm using a mix of aftermarket replacement filters, particularly the UNICEL model FG, which doesn't seem to affect the performance of this old DE filter system, but this is also indicative of what I'm having to do with all of the pool's plumbing thankfully, the pump motor is still running strong - but the Polaris is definitely dead. Best advice I've gotten so far from your site is help balancing and maintaining that balance in the pool chemistry. Got lots of horror sotries here alone, but in short, you've got another BBB devotee.

Thanks again, folks, and if you ever do come across that owner's manual, or know what is the proper amount of DE to add after a backwash, please let me know. Right now, I'm only guessing based on what some other folks "think" the right amount is. Join Date Nov Location St. Augustine, Fl Age 67 Posts 3, Pentair has changed part numbers on their filters when the brand it was sold under changed but the filters have remained essentially the same. You can download all the manuals for American, Purex, Pacfab, Starbrite, etc.

DE filters from the Pentair website.